ChemoGuardTM Chemotherapy Gown

Designed specifically for comfort and protection related to chemotherapy procedures

Designed to provide maximum protection from hazardous drugs during compounding, administering, handling waste, or cleaning up chemotherapeutic drug spills, our disposable gown offers the following:

  • Material performance which meets ASTM D6978-05 and EN 14126:2003 requirements
  • Non-stitched ultra sonic sleeve construction passes the stringent ASTM D6978-05 against Carmustine with no breakthrough up to 240 minutes
  • Virtually lint-free poly-coated spunbond
  • Generous fit with long sleeve and soft, fitted knit cuffs
  • Lightweight, closed-back design for full coverage and complete protection
  • Adjustable tie neck closure for ease of donning and doffing the gown
  • ChemoGuard™ branding identifies specific usability with chemotherapy drugs
  • Available in sterile and non-sterile configurations
Surgical Drapes
Surgical Gowns

High Performance Standards

GRI-Alleset Surgical Gowns provide clinicians with a range of materials and protection to meet every procedural requirement. Superior materials and innovative designs provide maximum protection and comfort that will provide clinicians security and confidence in even the most challenging procedures.

Industry Guidelines and Standards1

Following is information about standards and usage, as communicated by ONS, NIOSH, and USP (800) Guidelines.

Gowns used when handling hazardous chemotherapy agents are disposable and made of polyethylene-coated polypropylene or other laminate, lint-free, and material which does not allow permeability. The gown has a solid front with long sleeves and tight/closed elastic or knit cuffs. No seams or closures are present on the front of the gown that could permit drugs to pass through. Gowns are designed for a single use and should not be re-applied after removal.

Recommended Gown Use2

  • Administration
  • Dispensing
  • Disposal of Hazardous Drugs
  • Spill clean-up
  • Handling excreta
  • Transport

ASTM Standard Test Methods3

When selecting protective apparel, it’s important to note the difference between ASTM testing standards. While the testing procedures for both standards are similar and both require testing for up to four hours, some critical differences exist between the two. ASTM D6978 is traditionally used to measure the length of time it takes selected chemicals to permeate the glove material (breakthrough time), up to four hours. For this standard breakthrough, time is determined when the permeation rate reaches 0.01 μg/cm2/min. In the ASTM F739 Standard, the breakthrough time is determined when the permeation rate reaches 0.1 μg/cm2/min.

The ASTM D6978 standard is not only a more sensitive test method, it also outlines the drugs, concentration, and temperature by which the product must be tested, creating a higher standard due to a more sensitive permeation rate.

Want more info?  Ready to buy?